T1 - Variance analysis of photoplethysmography for blood pressure measurement
AU - Tjahjadi, Hendrana
AU - Ramli, Kalamullah
N1 - Funding Information:
ACKNOWLEDGMENT The author would like to thank the financial support provided by Universitas Indonesia trough the PITTA 2017 funding scheme under grant no. 857/UN2.R3.1/HKP.05.00/2017 managed by the Directorate for Research and Public Service (DPRM) Universitas Indonesia.
Publisher Copyright:
© 2018, Institute of Advanced Engineering and Science. All rights reserved.
PY - 2017/9
Y1 - 2017/9
N2 - The emergence of photoplethysmography for blood pressure estimation is offering a more convenient method. The elements of photoplethysmography waveform is crucial for blood pressure measurement. Several photoplethysmography elements are still not completely understood. The purpose of this study was to investigated corelation of photoplethysmography elements with blood pressure using statistical approach. Analysis of variance test (ANOVA) was conducted to see if there are any correlation between elements of photoplethysmography with blood pressure. This study used 10 volunteers without an ethical clearance. Photoplethysmography waveform and blood pressure measurements were taken through the patient monitor equipment DatascopeTM. As the result, value factor from the arithmetic is 35.67 and value factor from the table is 3.14. The value of Farithmetic (35.67) > Ftable (3.14). The correlation of diastolic time (Td) is negative with systolic arterial pressure (SAP) and the correlation of systolic amplitude (As) is positive with diastolic arterial pressure (DAP). The results showed elements of photoplethysmography can be used to estimation blood pressure.
AB - The emergence of photoplethysmography for blood pressure estimation is offering a more convenient method. The elements of photoplethysmography waveform is crucial for blood pressure measurement. Several photoplethysmography elements are still not completely understood. The purpose of this study was to investigated corelation of photoplethysmography elements with blood pressure using statistical approach. Analysis of variance test (ANOVA) was conducted to see if there are any correlation between elements of photoplethysmography with blood pressure. This study used 10 volunteers without an ethical clearance. Photoplethysmography waveform and blood pressure measurements were taken through the patient monitor equipment DatascopeTM. As the result, value factor from the arithmetic is 35.67 and value factor from the table is 3.14. The value of Farithmetic (35.67) > Ftable (3.14). The correlation of diastolic time (Td) is negative with systolic arterial pressure (SAP) and the correlation of systolic amplitude (As) is positive with diastolic arterial pressure (DAP). The results showed elements of photoplethysmography can be used to estimation blood pressure.
KW - Continuous blood pressure
KW - Noninvasive blood pressure
KW - Phoptoplethysmography
KW - Pulse wave analysis
UR - http://www.scopus.com/inward/record.url?scp=85044859116&partnerID=8YFLogxK
U2 - 10.11591/eecsi.4.999
DO - 10.11591/eecsi.4.999
M3 - Article
AN - SCOPUS:85044859116
SN - 2407-439X
VL - 4
SP - 110
EP - 113
JO - International Conference on Electrical Engineering, Computer Science and Informatics (EECSI)
JF - International Conference on Electrical Engineering, Computer Science and Informatics (EECSI)
ER -