Variance analysis of photoplethysmography for blood pressure measurement

Hendrana Tjahjadi, Kalamullah Ramli

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

1 Citation (Scopus)

Abstract

The emergence of photoplethysmography for blood pressure estimation is offering a more convenient method. The elements of photoplethysmography waveform is crucial for blood pressure measurement. Several photoplethysmography elements are still not completely understood. The purpose of this study was to investigated corelation of photoplethysmography elements with blood pressure using statistical approach. Analysis of variance test (ANOVA) was conducted to see if there are any correlation between elements of photoplethysmography with blood pressure. This study used 10 volunteers without an ethical clearance. Photoplethysmography waveform and blood pressure measurements were taken through the patient monitor equipment DatascopeTM. As the result, value factor from the arithmetic is 35.67 and value factor from the table is 3.14. The value of Farithmetic (35.67) > Ftable (3.14). The correlation of diastolic time (Td) is negative with systolic arterial pressure (SAP) and the correlation of systolic amplitude (As) is positive with diastolic arterial pressure (DAP). The results showed elements of photoplethysmography can be used to estimation blood pressure.

Original languageEnglish
Title of host publicationProceedings - 2017 4th International Conference on Electrical Engineering, Computer Science and Informatics, EECSI 2017
EditorsHatib Rahmawan, Mochammad Facta, Munawar A. Riyadi, Deris Stiawan
PublisherInstitute of Advanced Engineering and Science
ISBN (Electronic)9781538605486
DOIs
Publication statusPublished - 22 Dec 2017
Event4th International Conference on Electrical Engineering, Computer Science and Informatics, EECSI 2017 - Yogyakarta, Indonesia
Duration: 19 Sept 201721 Sept 2017

Publication series

NameInternational Conference on Electrical Engineering, Computer Science and Informatics (EECSI)
Volume2017-December
ISSN (Print)2407-439X

Conference

Conference4th International Conference on Electrical Engineering, Computer Science and Informatics, EECSI 2017
Country/TerritoryIndonesia
CityYogyakarta
Period19/09/1721/09/17

Keywords

  • Continuous blood pressure
  • Noninvasive blood pressure
  • Phoptoplethysmography
  • Pulse wave analysis

Fingerprint

Dive into the research topics of 'Variance analysis of photoplethysmography for blood pressure measurement'. Together they form a unique fingerprint.

Cite this