TY - JOUR
T1 - The simulation performance analysis of the EAHE open system with finned iron pipes
AU - Ginting Manik, T. U.H.S.
AU - Sitorus, T. B.
AU - Pasaribu, J.
AU - Pratama, N.
AU - Boer, W.
N1 - Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2020/1/21
Y1 - 2020/1/21
N2 - This study focuses on the Eart-Air Heat Exchanger (EAHE) which serves to reduce the energy consumption of air conditioning units, and analyze the thermal performance of air-ground heat exchangers using computational fluid dynamics modeling and validated against experimental observations. The simulation used is for flow-resisting, incompressible, turbulent, and 3-dimensional. Simulations were carried out using finned iron and PVC 3.0 "with a thickness of 2 mm and a length of 6.7 m. The simulation conditions were limited to the fluid flow with variations of the velocity of 1 m/s, 2 m/s, and 3 m/s. The average air temperature outlet from 3D simulation using Ansys 17.0 software was obtained 25.45 °C for the velocity of inlet air of 1 m/s, 25.73 °C for a velocity of 2 m/s, and 25.84°C for the velocity of inlet air of 3 m/s. The experimental results obtained of 25.99 °C for a velocity of 1 m/s, 26.33 °C for a velocity of 2 m/s, and 26.0 °C for the velocity of inlet air of 3 m/s. The highest deviations between the simulation and experimental results were obtained at -3.04% for the velocity of 3 m/s, and the lowest deviation is -10.28% for the velocity of 1 m/s. The average of COP value of the simulation results is 0.703 for the velocity of 1 m/s, 0.624 for the velocity of 2 m/s, and 0.774 for the velocity of 3 m/s, while the experimental results are obtained 0.6307 for the velocity of 1 m/s, 0.5417 for the velocity of 2 m/s, and 0.7504 for the velocity of 3 m/s. For the average effectiveness value of the simulation results were obtained of 0.956 for the velocity of 1 m/s, 0.940 for the velocity of 2 m/s and 0.960 for the velocity of 3 m/s, while the experimental results were obtained of 0.8590 for the velocity of 1 m/s, 0.8164 for the velocity of 2 m/s, and 0.8970 for the velocity of 3 m/s.
AB - This study focuses on the Eart-Air Heat Exchanger (EAHE) which serves to reduce the energy consumption of air conditioning units, and analyze the thermal performance of air-ground heat exchangers using computational fluid dynamics modeling and validated against experimental observations. The simulation used is for flow-resisting, incompressible, turbulent, and 3-dimensional. Simulations were carried out using finned iron and PVC 3.0 "with a thickness of 2 mm and a length of 6.7 m. The simulation conditions were limited to the fluid flow with variations of the velocity of 1 m/s, 2 m/s, and 3 m/s. The average air temperature outlet from 3D simulation using Ansys 17.0 software was obtained 25.45 °C for the velocity of inlet air of 1 m/s, 25.73 °C for a velocity of 2 m/s, and 25.84°C for the velocity of inlet air of 3 m/s. The experimental results obtained of 25.99 °C for a velocity of 1 m/s, 26.33 °C for a velocity of 2 m/s, and 26.0 °C for the velocity of inlet air of 3 m/s. The highest deviations between the simulation and experimental results were obtained at -3.04% for the velocity of 3 m/s, and the lowest deviation is -10.28% for the velocity of 1 m/s. The average of COP value of the simulation results is 0.703 for the velocity of 1 m/s, 0.624 for the velocity of 2 m/s, and 0.774 for the velocity of 3 m/s, while the experimental results are obtained 0.6307 for the velocity of 1 m/s, 0.5417 for the velocity of 2 m/s, and 0.7504 for the velocity of 3 m/s. For the average effectiveness value of the simulation results were obtained of 0.956 for the velocity of 1 m/s, 0.940 for the velocity of 2 m/s and 0.960 for the velocity of 3 m/s, while the experimental results were obtained of 0.8590 for the velocity of 1 m/s, 0.8164 for the velocity of 2 m/s, and 0.8970 for the velocity of 3 m/s.
UR - http://www.scopus.com/inward/record.url?scp=85079642194&partnerID=8YFLogxK
U2 - 10.1088/1757-899X/725/1/012013
DO - 10.1088/1757-899X/725/1/012013
M3 - Conference article
AN - SCOPUS:85079642194
SN - 1757-8981
VL - 725
JO - IOP Conference Series: Materials Science and Engineering
JF - IOP Conference Series: Materials Science and Engineering
IS - 1
M1 - 012013
T2 - 3rd Nommensen International Conference on Technology and Engineering 2019, NICTE 2019
Y2 - 25 July 2019 through 26 July 2019
ER -