TY - JOUR
T1 - The limit values for brightness and contrast adjustment in digital panoramic radiography
AU - Zahra, A. T.
AU - Syahraini, Syurri Innaddinna
AU - Kiswanjaya, Bramma
AU - Ustriyana, P.
N1 - Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2017/8/30
Y1 - 2017/8/30
N2 - There is an overall lack of studies about digital panoramic radiography. The application of image enhancement techniques is still being done based on the operator's preferences, since there is no objective limitation. The aim is to evaluate the limit values of the brightness and contrast adjustment in digital panoramic radiography. Digital panoramic radiographs were divided into three groups (dark, medium, and light), and the contrast and brightness adjustments were done using Digora for Windows. The static evaluations were done using three criteria: 1 if the image had lower quality, 2 if there was no difference and 3 if the image had better quality. The radiographic changes differed in each group depending on the initial imaging conditions. The brightness adjustment limit values in the dark and medium groups were -10 and +20, respectively, and -20 and +10 in the light group. The contrast adjustment limit values in all of the groups were -10 and +10.
AB - There is an overall lack of studies about digital panoramic radiography. The application of image enhancement techniques is still being done based on the operator's preferences, since there is no objective limitation. The aim is to evaluate the limit values of the brightness and contrast adjustment in digital panoramic radiography. Digital panoramic radiographs were divided into three groups (dark, medium, and light), and the contrast and brightness adjustments were done using Digora for Windows. The static evaluations were done using three criteria: 1 if the image had lower quality, 2 if there was no difference and 3 if the image had better quality. The radiographic changes differed in each group depending on the initial imaging conditions. The brightness adjustment limit values in the dark and medium groups were -10 and +20, respectively, and -20 and +10 in the light group. The contrast adjustment limit values in all of the groups were -10 and +10.
UR - http://www.scopus.com/inward/record.url?scp=85029579345&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/884/1/012044
DO - 10.1088/1742-6596/884/1/012044
M3 - Conference article
AN - SCOPUS:85029579345
SN - 1742-6588
VL - 884
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 1
M1 - 012044
T2 - 1st Physics and Technologies in Medicine and Dentistry Symposium, PTMDS 2017
Y2 - 15 July 2017 through 16 July 2017
ER -