TY - JOUR
T1 - The influence of wideband amplifier supply on the consistency level of multi-spectral fluctuation pattern
AU - Melinda,
AU - Tamsir, Agus Santoso
AU - Basari,
AU - Mahatidana, P.
AU - Gunawan, Dadang
N1 - Funding Information:
This study was supported by a grant from Hibah PITTA DRPM Universitas Indonesia; grant number: 2076/UN2.R12/HKP.05.00/2016.
Publisher Copyright:
© 2017 American Scientific Publishers All rights reserved.
PY - 2017
Y1 - 2017
N2 - This study discusses the influence of WBA (wide band amplifier) supply against the performance of consistency level of multi-spectral fluctuation pattern, which is the output of the MCS (Multi Frequency Capacitive Sensor). In order to obtain some significant impacts on the sensor output, there are several methods that are employed in this study. Firstly, the sensor equipment MSC is designed, followed by setting up the equipment used in this study. Furthermore, there will be some setting circuits of WBA supply by using two input sources, such as source of AC (alternating current) and DC (direct current). The material used is material mixture between H2O and HCl. In addition, the results will be analyzed statistically that the data is observed based on the value of HHF (high-high fluctuation) and fluctuations value in VMR (variance to mean ratio). Whereas, the result reveals that the WBA supply with battery supply performs the highest of consistency level fluctuations pattern compared to others WBA supply, which is the average value obtained by statistical observations is 98.67% and the value of VMR is 0.0073. It is noticeable to say that by achieving the biggest consistency value of multi spectral fluctuation pattern, then a comparison between two of different materials can perform well.
AB - This study discusses the influence of WBA (wide band amplifier) supply against the performance of consistency level of multi-spectral fluctuation pattern, which is the output of the MCS (Multi Frequency Capacitive Sensor). In order to obtain some significant impacts on the sensor output, there are several methods that are employed in this study. Firstly, the sensor equipment MSC is designed, followed by setting up the equipment used in this study. Furthermore, there will be some setting circuits of WBA supply by using two input sources, such as source of AC (alternating current) and DC (direct current). The material used is material mixture between H2O and HCl. In addition, the results will be analyzed statistically that the data is observed based on the value of HHF (high-high fluctuation) and fluctuations value in VMR (variance to mean ratio). Whereas, the result reveals that the WBA supply with battery supply performs the highest of consistency level fluctuations pattern compared to others WBA supply, which is the average value obtained by statistical observations is 98.67% and the value of VMR is 0.0073. It is noticeable to say that by achieving the biggest consistency value of multi spectral fluctuation pattern, then a comparison between two of different materials can perform well.
KW - Consistency Level
KW - Fluctuation Pattern
KW - Supply Amplifier
UR - http://www.scopus.com/inward/record.url?scp=85021098783&partnerID=8YFLogxK
U2 - 10.1166/asl.2017.9037
DO - 10.1166/asl.2017.9037
M3 - Article
AN - SCOPUS:85021098783
SN - 1936-6612
VL - 23
SP - 3758
EP - 3762
JO - Advanced Science Letters
JF - Advanced Science Letters
IS - 4
ER -