TY - JOUR
T1 - The influence of storage duration on the setting time of type 1 alginate impression material
AU - Rahmadina, A.
AU - Prawirowinoto, Siti Triaminingsih
AU - Irawan, Bambang
N1 - Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2017/8/30
Y1 - 2017/8/30
N2 - Alginate is one of the most commonly used dental impression materials; however, its setting time is subject to change depending on storage conditions and duration. This creates problems because consumer carelessness can affect alginate shelf life and quality. In the present study, the setting times of two groups of type I alginate with different expiry dates was tested. The first group consisted of 11 alginate specimens that had not yet passed the expiry date, and the second group consisted of alginates that had passed the expiry date. The alginate powder was mixed with distilled water, poured into a metal ring, and tested with a polished rod of poly-methyl methacrylate. Statistical analysis showed a significant difference (p<0.05) between the setting times of the alginate that had not passed the expiry date (157 ± 3 seconds) and alginate that had passed the expiry date (144 ± 2 seconds). These findings indicate that storage duration can affect alginate setting time.
AB - Alginate is one of the most commonly used dental impression materials; however, its setting time is subject to change depending on storage conditions and duration. This creates problems because consumer carelessness can affect alginate shelf life and quality. In the present study, the setting times of two groups of type I alginate with different expiry dates was tested. The first group consisted of 11 alginate specimens that had not yet passed the expiry date, and the second group consisted of alginates that had passed the expiry date. The alginate powder was mixed with distilled water, poured into a metal ring, and tested with a polished rod of poly-methyl methacrylate. Statistical analysis showed a significant difference (p<0.05) between the setting times of the alginate that had not passed the expiry date (157 ± 3 seconds) and alginate that had passed the expiry date (144 ± 2 seconds). These findings indicate that storage duration can affect alginate setting time.
UR - http://www.scopus.com/inward/record.url?scp=85029599293&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/884/1/012096
DO - 10.1088/1742-6596/884/1/012096
M3 - Conference article
AN - SCOPUS:85029599293
SN - 1742-6588
VL - 884
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 1
M1 - 012096
T2 - 1st Physics and Technologies in Medicine and Dentistry Symposium, PTMDS 2017
Y2 - 15 July 2017 through 16 July 2017
ER -