Study Characteristics of Disturbance in Frequency 9-150 kHz Generated by Household Appliance at Different points in Building Installation System

Galuh Prameswari, M. Luthvan Hood, Budi Sudiarto

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Nowadays there are many household appliances use inverter technology in order to improve energy efficiency. However, after being examined by the researcher, the use of this technology can generate disturbances in the frequency range 9-150 kHz. The disturbance generated by appliances may either increase or decrease due to the interaction of many appliances in a shared network. This study focuses on observing the characteristics of the disturbance in the frequency range 9-150 kHz generated by household appliances at a different point in building installation system. A vacuum cleaner is used as a disturbance source appliance and hotel which has many rooms operating of some household appliances is chosen as an object of measurement. The measurement is conducted at three points room socket, room panels, and floor panels. The PC Based oscilloscope is used to obtained time-domain signal and by using FFT the time domain signal then transformed to the frequency domain to the frequency spectrum of disturbance in the frequency range 9-150 kHz. The measurement shows that the disturbance characteristics generated by vacuum cleaner at three-point of hotel installation system are different due to the interaction of other appliances in the shared network. the disturbance of vacuum cleaner decreases 39.45 mV between socket and room panel and 20.225 mV between room panel and floor panel.

Original languageEnglish
Title of host publicationICECOS 2019 - 3rd International Conference on Electrical Engineering and Computer Science, Proceeding
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages358-362
Number of pages5
ISBN (Electronic)9781728147147
DOIs
Publication statusPublished - Oct 2019
Event3rd International Conference on Electrical Engineering and Computer Science, ICECOS 2019 - Batam, Indonesia
Duration: 2 Oct 20193 Oct 2019

Publication series

NameICECOS 2019 - 3rd International Conference on Electrical Engineering and Computer Science, Proceeding

Conference

Conference3rd International Conference on Electrical Engineering and Computer Science, ICECOS 2019
Country/TerritoryIndonesia
CityBatam
Period2/10/193/10/19

Keywords

  • Disturbances 9-150 kHz
  • FFT
  • Household Appliances
  • Vacuum Cleaners

Fingerprint

Dive into the research topics of 'Study Characteristics of Disturbance in Frequency 9-150 kHz Generated by Household Appliance at Different points in Building Installation System'. Together they form a unique fingerprint.

Cite this