T1 - Startup characteristics of a water loop heat pipe with dual heat sources for battery thermal management system in electric vehicle
AU - Fathoni, A. M.
AU - Hendrayanto, P. A.
AU - Aliefiansyah, M. S.
AU - Putra, N.
N1 - Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2024
Y1 - 2024
N2 - The usage of electric vehicles has significantly reduced emissions of greenhouse gases and other pollutants. However, the high heat release generated by the electric vehicle batteries poses a challenge. To solve this problem, scientists have created a passive cooling thermal management system specifically for electric vehicle based on heat pipes, particularly loop heat pipes. A battery pack often consists of several battery modules, which results in multiple heat sources being dispersed according to their power capacity. Startup behavior of loop heat pipe has been investigated extensively in the literature. However, most of the studies use only one heat source. This paper aims to fill the research gap, particularly when the system is implemented in dual heat sources managed by only one evaporator. To achieve the research objectives, a custom loop heat pipe was constructed. This cooling system's design is briefly described. The evaporator is made of copper, deionized water was selected as the working fluid because of its high merit number, which indicates strong performance as a heat pipe working fluid and the stainless-steel wire mesh serves as the porous wick. Battery simulator was built using aluminum material and a cartridge heater to mimic the heat produced by the battery. Two case studies were done. First, only one battery simulator was used. Second, two battery simulators were placed on both sides of the evaporator. A type-K thermocouple attached to the NI DAQ 9214 module was used to measure the temperature while the electric heat load varied between 10 W and 50 W. The study investigated the interaction between the heat load distribution and the startup behavior of the loop heat pipe. Startup behavior is crucial for the performance of the loop heat pipe. Based on the experimental results, the loop heat pipe demonstrates outstanding startup performance. It can effectively initiate operation even at a minimal heat load as low as 30 W for the first and second case study. The findings of the study indicate that the dual heat source arrangement effectively mitigates overshoot temperatures and enhances heat transfer performance by increasing the contact area.
AB - The usage of electric vehicles has significantly reduced emissions of greenhouse gases and other pollutants. However, the high heat release generated by the electric vehicle batteries poses a challenge. To solve this problem, scientists have created a passive cooling thermal management system specifically for electric vehicle based on heat pipes, particularly loop heat pipes. A battery pack often consists of several battery modules, which results in multiple heat sources being dispersed according to their power capacity. Startup behavior of loop heat pipe has been investigated extensively in the literature. However, most of the studies use only one heat source. This paper aims to fill the research gap, particularly when the system is implemented in dual heat sources managed by only one evaporator. To achieve the research objectives, a custom loop heat pipe was constructed. This cooling system's design is briefly described. The evaporator is made of copper, deionized water was selected as the working fluid because of its high merit number, which indicates strong performance as a heat pipe working fluid and the stainless-steel wire mesh serves as the porous wick. Battery simulator was built using aluminum material and a cartridge heater to mimic the heat produced by the battery. Two case studies were done. First, only one battery simulator was used. Second, two battery simulators were placed on both sides of the evaporator. A type-K thermocouple attached to the NI DAQ 9214 module was used to measure the temperature while the electric heat load varied between 10 W and 50 W. The study investigated the interaction between the heat load distribution and the startup behavior of the loop heat pipe. Startup behavior is crucial for the performance of the loop heat pipe. Based on the experimental results, the loop heat pipe demonstrates outstanding startup performance. It can effectively initiate operation even at a minimal heat load as low as 30 W for the first and second case study. The findings of the study indicate that the dual heat source arrangement effectively mitigates overshoot temperatures and enhances heat transfer performance by increasing the contact area.
KW - Battery thermal management system
KW - Dual heat sources
KW - Loop heat pipe
KW - Rectangular evaporator
KW - Startup characteristics
KW - Thermal performance
UR - http://www.scopus.com/inward/record.url?scp=85199379334&partnerID=8YFLogxK
U2 - 10.1088/1755-1315/1372/1/012013
DO - 10.1088/1755-1315/1372/1/012013
M3 - Conference article
AN - SCOPUS:85199379334
SN - 1755-1307
VL - 1372
JO - IOP Conference Series: Earth and Environmental Science
JF - IOP Conference Series: Earth and Environmental Science
IS - 1
M1 - 012013
T2 - International Conference on Sustainable Energy and Green Technology 2023, SEGT 2023
Y2 - 10 December 2023 through 13 December 2023