TY - GEN
T1 - Preparation of feedstock using beeswax binder and SS 17-4PH powder for fabrication process of orthodontic bracket by metal injection molding
AU - Supriadi, S.
AU - Dewantoro, S.
AU - Mawardi, F. Arief
AU - Irawan, B.
AU - Doloksaribu, M.
AU - Suharno, B.
N1 - Publisher Copyright:
© 2019 Author(s).
PY - 2019/4/9
Y1 - 2019/4/9
N2 - The need for orthodontic brackets in Indonesia is very high due to the high prevalence of malocclusion sufferers in Indonesia. In this research, orthodontic brackets were fabricated by Metal Injection Molding method using Stainless Steel (SS) 17-4 PH powder and the variation of binder system as the feedstocks. The purpose of this study was to develop the optimum of the local binder systems as the feedstocks preparation for the fabrication of orthodontic brackets. Several parameters that could affect fabrication has been studied, such as: the composition of the binder system with the relation with torque and viscosity of the feedstock. The mixture of Beeswax (BW) as a local raw material, Paraffin Wax (PW), Low-Linear Density Polyethylene (LLDPE), Ethylene Vinyl Acetate (EVA), and Stearic Acid (SA) were mixed with SS 17-4PH powder in various compositions to produce the optimal feedstock properties. The compositions was K1 (PW 64%, HDPE 35%, SA 1%), K2 (30% PW, 30% BW, 30% LLDPE, 5% EVA, 5% SA), K3 (PW 20%, BW 30 %, LLDPE 30%, EVA 15%, SA 5%), and K4 (PW 20%, BW 30%, LLDPE 40%, EVA 5%, SA 5%) with powder loading of 60 vol. %. The feedstocks were injected into orthodontic bracket molds and the effect on their rheological properties was observed. It was found that the composition of the K4 binder system had an optimal torque and viscosity value of 5.63 Nm and 19.43Pa.s, respectively. Moreover, the torque and viscosity values were close to the values of commercial feedstocks (i.e. 5.52 Nm and 19.04Pa.s) that produce green parts with a good shape stability and minimum defects. With an excellent Melting Flow Index (MFI) of LLDPE, the feedstock generated a good mold-ability and crack resistance of the brackets. These results indicated that the composition of the K4 binder system is suitable for use as an orthodontic bracket feedstock.
AB - The need for orthodontic brackets in Indonesia is very high due to the high prevalence of malocclusion sufferers in Indonesia. In this research, orthodontic brackets were fabricated by Metal Injection Molding method using Stainless Steel (SS) 17-4 PH powder and the variation of binder system as the feedstocks. The purpose of this study was to develop the optimum of the local binder systems as the feedstocks preparation for the fabrication of orthodontic brackets. Several parameters that could affect fabrication has been studied, such as: the composition of the binder system with the relation with torque and viscosity of the feedstock. The mixture of Beeswax (BW) as a local raw material, Paraffin Wax (PW), Low-Linear Density Polyethylene (LLDPE), Ethylene Vinyl Acetate (EVA), and Stearic Acid (SA) were mixed with SS 17-4PH powder in various compositions to produce the optimal feedstock properties. The compositions was K1 (PW 64%, HDPE 35%, SA 1%), K2 (30% PW, 30% BW, 30% LLDPE, 5% EVA, 5% SA), K3 (PW 20%, BW 30 %, LLDPE 30%, EVA 15%, SA 5%), and K4 (PW 20%, BW 30%, LLDPE 40%, EVA 5%, SA 5%) with powder loading of 60 vol. %. The feedstocks were injected into orthodontic bracket molds and the effect on their rheological properties was observed. It was found that the composition of the K4 binder system had an optimal torque and viscosity value of 5.63 Nm and 19.43Pa.s, respectively. Moreover, the torque and viscosity values were close to the values of commercial feedstocks (i.e. 5.52 Nm and 19.04Pa.s) that produce green parts with a good shape stability and minimum defects. With an excellent Melting Flow Index (MFI) of LLDPE, the feedstock generated a good mold-ability and crack resistance of the brackets. These results indicated that the composition of the K4 binder system is suitable for use as an orthodontic bracket feedstock.
KW - binder systems
KW - feedstock
KW - metal injection molding
KW - orthodontic bracket
UR - http://www.scopus.com/inward/record.url?scp=85064803673&partnerID=8YFLogxK
U2 - 10.1063/1.5096697
DO - 10.1063/1.5096697
M3 - Conference contribution
AN - SCOPUS:85064803673
T3 - AIP Conference Proceedings
BT - 3rd Biomedical Engineering''s Recent Progress in Biomaterials, Drugs Development, and Medical Devices
A2 - Wulan, Praswasti P.D.K.
A2 - Gozan, Misri
A2 - Astutiningsih, Sotya
A2 - Ramahdita, Ghiska
A2 - Dhelika, Radon
A2 - Kreshanti, Prasetyanugraheni
PB - American Institute of Physics Inc.
T2 - 3rd International Symposium of Biomedical Engineering''s Recent Progress in Biomaterials, Drugs Development, and Medical Devices, ISBE 2018
Y2 - 6 August 2018 through 8 August 2018
ER -