T1 - Point dose measurements for brachytherapy with a cylinder applicator
AU - Rahmawati, R.
AU - Wibowo, W. E.
AU - Pawiro, S. A.
N1 - Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2020/1/29
Y1 - 2020/1/29
N2 - Point dose measurements were conducted in High dose-rate (HDR) brachytherapy with a cylinder applicator using an EBT3 gafchromic film. The main objectives of this study were to determine the characteristics of an EBT3 film and evaluate the treatment dose of brachytherapy between manual and normalized measurements. Evaluation of the dose treatment was performed by comparing the dose values at four measurements (namely A1, A2, A3, and A4) points with the dose values after being normalized. The first two points A1 and A2 are the prescription points to the right and left of the cylinder applicator. The dose measurements at these two points were measured for three variations of distance (13, 14, and 15 mm) to the source of brachytherapy. The other two points, A3 and A4, are located at a distance of 1.5 cm above the two points, A2 and A1. The most suitable calibration for point dose measurements is the 13-mm distance, which results in the discrepancy values for points A1, A2, A3, and A4 are -0.37 %, -3.40 %, -1.39 %, and -1.54 %, respectively.
AB - Point dose measurements were conducted in High dose-rate (HDR) brachytherapy with a cylinder applicator using an EBT3 gafchromic film. The main objectives of this study were to determine the characteristics of an EBT3 film and evaluate the treatment dose of brachytherapy between manual and normalized measurements. Evaluation of the dose treatment was performed by comparing the dose values at four measurements (namely A1, A2, A3, and A4) points with the dose values after being normalized. The first two points A1 and A2 are the prescription points to the right and left of the cylinder applicator. The dose measurements at these two points were measured for three variations of distance (13, 14, and 15 mm) to the source of brachytherapy. The other two points, A3 and A4, are located at a distance of 1.5 cm above the two points, A2 and A1. The most suitable calibration for point dose measurements is the 13-mm distance, which results in the discrepancy values for points A1, A2, A3, and A4 are -0.37 %, -3.40 %, -1.39 %, and -1.54 %, respectively.
KW - brachytherapy
KW - calibration
KW - dose
KW - EBT3 gafchromic film
KW - point dose
KW - TPS
UR - http://www.scopus.com/inward/record.url?scp=85079630051&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/1442/1/012018
DO - 10.1088/1742-6596/1442/1/012018
M3 - Conference article
AN - SCOPUS:85079630051
SN - 1742-6588
VL - 1442
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 1
M1 - 012018
T2 - Basic and Applied Sciences Interdisciplinary Conference 2017, BASIC 2017
Y2 - 18 August 2017 through 19 August 2017
ER -