TY - JOUR
T1 - Optic performance of single and double-glazed laminated glass in tropical climate
AU - Halida Ibrahim, Nurul
AU - Candra Dewi, Ova
N1 - Funding Information:
This research was funded by PUTI-UI Saintekes grant research under the contract no: NKB-2439/UN2.RST/HKP.05.00/2020. The authors gratefully thank Department of Architecture, Engineering Faculty, Universitas Indonesia
Publisher Copyright:
© The Authors, published by EDP Sciences, 2020.
PY - 2020/11/25
Y1 - 2020/11/25
N2 - Validation model was generated by WINDOW 7.6 software to simulate the temperature changes of laminated glass. This approach is used as a validation model to compare the real time temperature changes observed. The parameter in the test were clear laminated glass and coloured laminated glass with using singleand double-glazed technology to assess the impact of optic glass, including U-Value, SHGC, and additional layer application of laminated Glass (Double Glazing Technology) in building temperature changes for creating thermal comfort. The results showed that single glazed technology application on clear laminated glass adjust the room temperature between 30.2°C to 31.4°C. In comparison, single colour laminated glass technology application set the room temperature 27.7°C to 28.5°C. Interestingly, the double-glazed application reduced the indoor temperature between 27.1°C to 28.5°C. These results showed that buildings' significant thermal performance could be accomplished by applying doubleglazed technology. Nevertheless, double glazed technology was not suggested to apply in all of the skin of tropical building design due to the high-cost issues.
AB - Validation model was generated by WINDOW 7.6 software to simulate the temperature changes of laminated glass. This approach is used as a validation model to compare the real time temperature changes observed. The parameter in the test were clear laminated glass and coloured laminated glass with using singleand double-glazed technology to assess the impact of optic glass, including U-Value, SHGC, and additional layer application of laminated Glass (Double Glazing Technology) in building temperature changes for creating thermal comfort. The results showed that single glazed technology application on clear laminated glass adjust the room temperature between 30.2°C to 31.4°C. In comparison, single colour laminated glass technology application set the room temperature 27.7°C to 28.5°C. Interestingly, the double-glazed application reduced the indoor temperature between 27.1°C to 28.5°C. These results showed that buildings' significant thermal performance could be accomplished by applying doubleglazed technology. Nevertheless, double glazed technology was not suggested to apply in all of the skin of tropical building design due to the high-cost issues.
UR - http://www.scopus.com/inward/record.url?scp=85097653408&partnerID=8YFLogxK
U2 - 10.1051/e3sconf/202021104004
DO - 10.1051/e3sconf/202021104004
M3 - Conference article
AN - SCOPUS:85097653408
SN - 2555-0403
VL - 211
JO - E3S Web of Conferences
JF - E3S Web of Conferences
M1 - 04004
T2 - 1st International Symposium of Earth, Energy, Environmental Science and Sustainable Development, JESSD 2020
Y2 - 28 September 2020 through 30 September 2020
ER -