TY - JOUR
T1 - Nilai Rerata Vascular Pedicle Width, Vascular Pedicle-Cardiac Ratio Vascular Pedicle-Thoracic Ratio Orang Dewasa Normal Indonesia Studi di RS dr. Cipto Mangunkusomo
AU - Zunera, Rommy
AU - Afifi, Rahmi
AU - Madjid, Amir S.
AU - Prihartono, Joedo
AU - Wulani, Vally
AU - Prasetyo, Marcel
PY - 2015/12
Y1 - 2015/12
N2 - Vascular pedicle width (VPW) is the distance, from a perpendicular line at the takeoff point of the left subclavian artery off the aorta to the point at which the superior vena cava. Measurement of VPW on chestx-ray is relatively non-invasive, fast and easy technique as hypervolemia predictor. The purpose of thisstudy is to know the mean VPW value of normal Indonesian adult. There are two measurement methodswas performed, the first is a measurements of single VPW, which its accuracy is limited to digital chest x-ray.The second method for non digital chest x-ray utility is a ratio measurement i.e. the ratio of cardiac vascularpedicle-(VPCR), and vascular pedicle-thoracic ratio (VPTR). Similar measurements method performed onthe thoracic CT scan topogram (AP chest x-ray) and thoracic CT scan, then compared both of measurementto evaluate the accuracy of topogram measurement as thoracic CT scan as gold standard. Data from 104 PAchest x-ray of normal subjects and 103 thoracic CT scan of selected subjects. On PA chest x-ray obtainedmean VPW 48,0±5.5mm, mean VPCR 40.3±4.6%, and mean VPTR 17.2±1.7%. On CT scan topogramobtained mean VPW 50,3±6.2mm, mean VPTR 45±5.1%, and mean VPTR 19.8±2.5%. On thoracic CT scanobtained mean VPW 50.4±6.1mm. Measurements on the AP chest x-ray about 10% greater than in the PAchest x-ray, and measurement of VPW on conventional chest x-ray aproved to have high accuracy.
AB - Vascular pedicle width (VPW) is the distance, from a perpendicular line at the takeoff point of the left subclavian artery off the aorta to the point at which the superior vena cava. Measurement of VPW on chestx-ray is relatively non-invasive, fast and easy technique as hypervolemia predictor. The purpose of thisstudy is to know the mean VPW value of normal Indonesian adult. There are two measurement methodswas performed, the first is a measurements of single VPW, which its accuracy is limited to digital chest x-ray.The second method for non digital chest x-ray utility is a ratio measurement i.e. the ratio of cardiac vascularpedicle-(VPCR), and vascular pedicle-thoracic ratio (VPTR). Similar measurements method performed onthe thoracic CT scan topogram (AP chest x-ray) and thoracic CT scan, then compared both of measurementto evaluate the accuracy of topogram measurement as thoracic CT scan as gold standard. Data from 104 PAchest x-ray of normal subjects and 103 thoracic CT scan of selected subjects. On PA chest x-ray obtainedmean VPW 48,0±5.5mm, mean VPCR 40.3±4.6%, and mean VPTR 17.2±1.7%. On CT scan topogramobtained mean VPW 50,3±6.2mm, mean VPTR 45±5.1%, and mean VPTR 19.8±2.5%. On thoracic CT scanobtained mean VPW 50.4±6.1mm. Measurements on the AP chest x-ray about 10% greater than in the PAchest x-ray, and measurement of VPW on conventional chest x-ray aproved to have high accuracy.
UR - http://journal.ui.ac.id/index.php/eJKI/article/view/5644
U2 - 10.23886/ejki.3.5644.
DO - 10.23886/ejki.3.5644.
M3 - Article
SN - 2338-1426
VL - 3
JO - eJournal Kedokteran Indonesia
JF - eJournal Kedokteran Indonesia
IS - 3
ER -