@inproceedings{45b1a9b3f0904fef921f035371f308e0,
title = "Experimental study on counter current flow limitation based on variation of gap size in narrow rectangular channel during quenching process",
abstract = "The Effect of gap size to counter current flow limitation (CCFL) in vertical rectangular channel was studied in this paper. Experiment was conducted by using two vertical plate with 1 mm, 2 mm, and 3 mm narrow gap. The initial temperature of plate was decided at 600°C. Flow rate and temperature of cooling water were controlled about 0.09 L/s and 90°C respectively. Non-dimensional superficial velocity for water is 0.05-0.09 and non-dimensional superficial velocity for vapor is 3.20-3.2. The result shows that the existence of CCFL in the vertical rectangular narrow channels. A new correlation for CCFL base on Wallis has been proposed.",
keywords = "CCFL, Gap, Narrow, Quenching, Superficial",
author = "Mulya Juarsa and Putra, {Nandy Setiadi Djaya} and Harinaldi and Antariksawan, {Anhar Riza}",
year = "2014",
doi = "10.4028/www.scientific.net/AMM.590.613",
language = "English",
isbn = "9783038351511",
series = "Applied Mechanics and Materials",
publisher = "Trans Tech Publications Ltd",
pages = "613--617",
booktitle = "Innovative Solutions in the Field of Engineering Sciences",
note = "2014 International Conference on Applied Mechanics and Mechanical Automation, AMMA 2014 ; Conference date: 20-05-2014 Through 21-05-2014",
}