TY - JOUR
T1 - Experimental study of multi-fin heat pipe heat exchanger for energy efficiency in operating room air systems
AU - Muhammaddiyah, Syahrul
AU - Winarta, Adi
AU - Putra, Nandy Setiadi Djaya
N1 - Publisher Copyright:
© IJTech 2018.
PY - 2018/4/1
Y1 - 2018/4/1
N2 - This study was conduct to identify the effectiveness and heat recovery values of heat pipe heat exchangers (HPHEs) in heating ventilating air conditioning (HVAC) ducting systems. HPHEs are passive modules which provide the energy recovery function in HVAC systems. In this research the HPHE module consist of 42 heat pipe tubes equipped with 120 wavy fins on the evaporator and condenser sections. In this study the HPHE module was tested with a three-row configuration design, and at inlet airflow temperatures of 28, 30, 35, 40, and 45°C. The velocity of inlet air also varied, at 1, 1.5, and 2 m/s. The results show that in the three-row configuration the inlet temperature decreased by a maximum of 10.3°C. This configuration also has an HPHE effectiveness value of between 47.9 and 54.4%. The highest effectiveness value (54.4%) was obtained at inlet air velocity and temperature of 1 m/s and 45°C, respectively. The highest HPHE heat recovery value was 5,368 W at 2 m/s inlet air velocity, giving a 51.7% HPHE effectiveness rating. This HPHE system can be considered as saving energy for HVAC systems.
AB - This study was conduct to identify the effectiveness and heat recovery values of heat pipe heat exchangers (HPHEs) in heating ventilating air conditioning (HVAC) ducting systems. HPHEs are passive modules which provide the energy recovery function in HVAC systems. In this research the HPHE module consist of 42 heat pipe tubes equipped with 120 wavy fins on the evaporator and condenser sections. In this study the HPHE module was tested with a three-row configuration design, and at inlet airflow temperatures of 28, 30, 35, 40, and 45°C. The velocity of inlet air also varied, at 1, 1.5, and 2 m/s. The results show that in the three-row configuration the inlet temperature decreased by a maximum of 10.3°C. This configuration also has an HPHE effectiveness value of between 47.9 and 54.4%. The highest effectiveness value (54.4%) was obtained at inlet air velocity and temperature of 1 m/s and 45°C, respectively. The highest HPHE heat recovery value was 5,368 W at 2 m/s inlet air velocity, giving a 51.7% HPHE effectiveness rating. This HPHE system can be considered as saving energy for HVAC systems.
KW - HVAC
KW - Heat pipe heat exchanger
KW - Heat recovery
KW - Multi-wavy fins
KW - Operating room
UR - http://www.scopus.com/inward/record.url?scp=85046849311&partnerID=8YFLogxK
U2 - 10.14716/ijtech.v9i2.1150
DO - 10.14716/ijtech.v9i2.1150
M3 - Article
AN - SCOPUS:85046849311
SN - 2086-9614
VL - 9
SP - 422
EP - 429
JO - International Journal of Technology
JF - International Journal of Technology
IS - 2
ER -