TY - JOUR
T1 - Effects of Void Characteristics on Compressive Strength of Permeable Mortar Paver and Design Recommendation for Parking Area
AU - Marulitua, B. Y.
AU - Muslim, F.
AU - Sagita, L.
N1 - Funding Information:
Authors would like to thank Universitas Indonesia for funding this research under the PUTI 2020 scheme.
Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2021/8/2
Y1 - 2021/8/2
N2 - This study aims to analyse the effect of void characteristics on the compressive strength of permeable mortar paversand provide design recommendations for permeable mortar pavers to be applied in parking areas. In this study, the specimens were cast in steel moulds with the void percentages of 5%, 10% and 15%, and tested for compressive strength. For the design recommendations, the permeable mortar paver installation was carried out based on the result of laboratory testing and from some literature studies. The result of this study indicated that the lower thevoid percentages, the higher the compressive strength of the specimens. The use of plastic straws to make voidsgavehigher compressive strength compared to specimens with bamboo straws. For the application, the recommended form for the permeable mortar paver is a 21 cm × 21 cm squared pre-cast paving block which contains four 1 1/2 PVC pipes as a void maker. Finally, field studies are necessary to evaluate the design recommendation of permeable mortar paver.
AB - This study aims to analyse the effect of void characteristics on the compressive strength of permeable mortar paversand provide design recommendations for permeable mortar pavers to be applied in parking areas. In this study, the specimens were cast in steel moulds with the void percentages of 5%, 10% and 15%, and tested for compressive strength. For the design recommendations, the permeable mortar paver installation was carried out based on the result of laboratory testing and from some literature studies. The result of this study indicated that the lower thevoid percentages, the higher the compressive strength of the specimens. The use of plastic straws to make voidsgavehigher compressive strength compared to specimens with bamboo straws. For the application, the recommended form for the permeable mortar paver is a 21 cm × 21 cm squared pre-cast paving block which contains four 1 1/2 PVC pipes as a void maker. Finally, field studies are necessary to evaluate the design recommendation of permeable mortar paver.
KW - Design Recommendation
KW - Parking Lot
KW - Permeable Mortar Paver
UR - http://www.scopus.com/inward/record.url?scp=85112502824&partnerID=8YFLogxK
U2 - 10.1088/1755-1315/794/1/012048
DO - 10.1088/1755-1315/794/1/012048
M3 - Conference article
AN - SCOPUS:85112502824
SN - 1755-1307
VL - 794
JO - IOP Conference Series: Earth and Environmental Science
JF - IOP Conference Series: Earth and Environmental Science
IS - 1
M1 - 012048
T2 - 4th International Conference on Eco Engineering Development 2020, ICEED 2020
Y2 - 10 November 2020 through 11 November 2020
ER -