This paper analyzes the effect of the load and initial position of the Permanent Magnet Synchronous Motor Control (PMSM) control system when the PMSM is used as a vehicle on the flat road and uphill. The control system that will be analyzed uses Proportional Integral (PI) as a current controller and incremental encoder as a sensor. The results prove that the initial rotor positions affect the motor current.

Original languageEnglish
Title of host publication2nd International Conference on Smart Grid and Smart Cities, ICSGSC 2018
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages95-99
Number of pages5
ISBN (Electronic)9781538681022
DOIs
Publication statusPublished - 20 Nov 2018
Event2nd International Conference on Smart Grid and Smart Cities, ICSGSC 2018 - Kuala Lumpur, Malaysia
Duration: 12 Aug 201814 Aug 2018

Publication series

Name2nd International Conference on Smart Grid and Smart Cities, ICSGSC 2018

Conference

Conference2nd International Conference on Smart Grid and Smart Cities, ICSGSC 2018
Country/TerritoryMalaysia
CityKuala Lumpur
Period12/08/1814/08/18

Keywords

  • PMSM
  • current
  • incremental encoder
  • initial position
  • synchronization
  • vector control