TY - JOUR
T1 - Effect of implantation Ti-6Al-4V ELI in femoral bone defect regeneration of Sprague Dawley rat
AU - Nyoman Jujur, I.
AU - Damisih,
AU - Devy, Kartika
AU - Suha, Shovy
AU - Bachtiar, Boy Muchlis
AU - Bachtiar, Endang Winiati
N1 - Publisher Copyright:
© 2020 Journal of Advanced Pharmaceutical Technology & Research | Published by Wolters Kluwer-Medknow.
Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2020/10/1
Y1 - 2020/10/1
N2 - Ti-6Al-4V ELI is one of the most commonly used dental implant restore function. The solution treatment temperature variation can significantly increase the strength, but it is not yet known the effect of these temperature variations on the alloy's biocompatibility properties. Twelve female Sprague Dawley rats were divided into six groups as follows: the treated group, the control group, and the defect group without implant material. In the treated group, the femur bone defect was implanted with as-cast Ti-6Al-4V ELI, 850°C, 950°C, and 1050°C heat-treated Ti-6Al-4V ELI implant material. The rats were euthanized after 30 days postimplantation and evaluated histologically. The results show that the histological scoring of the specimen for femur defect without implant material is 2 (fibrous union and fibrocartilaginous), score with implant as-cast is 2.5, the sample with 850°C heat treatment material is 2.5, 950°C is 2.5, and the temperature at 1050°C is 2.5. The score of 2.5 is between score 2 and score 3: hemorrhage, fibrous union, fibrocartilaginous microhemorrhage, and mineralized cartilage union. In conclusion, there is no effect of different heat treatment temperatures for Ti-6Al-4V ELI implant material in rat bone regeneration's maturation level.
AB - Ti-6Al-4V ELI is one of the most commonly used dental implant restore function. The solution treatment temperature variation can significantly increase the strength, but it is not yet known the effect of these temperature variations on the alloy's biocompatibility properties. Twelve female Sprague Dawley rats were divided into six groups as follows: the treated group, the control group, and the defect group without implant material. In the treated group, the femur bone defect was implanted with as-cast Ti-6Al-4V ELI, 850°C, 950°C, and 1050°C heat-treated Ti-6Al-4V ELI implant material. The rats were euthanized after 30 days postimplantation and evaluated histologically. The results show that the histological scoring of the specimen for femur defect without implant material is 2 (fibrous union and fibrocartilaginous), score with implant as-cast is 2.5, the sample with 850°C heat treatment material is 2.5, 950°C is 2.5, and the temperature at 1050°C is 2.5. The score of 2.5 is between score 2 and score 3: hemorrhage, fibrous union, fibrocartilaginous microhemorrhage, and mineralized cartilage union. In conclusion, there is no effect of different heat treatment temperatures for Ti-6Al-4V ELI implant material in rat bone regeneration's maturation level.
KW - Bone regeneration
KW - heat treatment
KW - Ti-6Al-4V ELI
KW - titanium implant
UR - http://www.scopus.com/inward/record.url?scp=85094614481&partnerID=8YFLogxK
U2 - 10.4103/japtr.JAPTR_74_20
DO - 10.4103/japtr.JAPTR_74_20
M3 - Article
AN - SCOPUS:85094614481
SN - 0110-5558
VL - 11
SP - 202
EP - 206
JO - Journal of Advanced Pharmaceutical Technology and Research
JF - Journal of Advanced Pharmaceutical Technology and Research
IS - 4
ER -