TY - JOUR
T1 - Direct electrochemical oxidation of proteins at conductive diamond electrodes
AU - Chiku, Masanobu
AU - Anggraningrum, Ivandini Tribidasari
AU - Kamiya, Akihide
AU - Fujishima, Akira
AU - Einaga, Yasuaki
PY - 2008/1/15
Y1 - 2008/1/15
N2 - Direct oxidation peaks relating to proteins have been clearly observed by exploiting H-terminated boron-doped diamond (BDD) electrodes. Hydrogen generation by reduction treatment was enabled to provide the possibility of using BDD. The pH dependence of bovine serum albumin (BSA) oxidation suggested that the oxidation involved of at least three redox-active amino acid residues (cysteine, tryptophan and tyrosine). Furthermore, the electrochemical detection of not only BSA but also immunosuppressive acidic protein (IAP, a cancer marker) was demonstrated by using cyclic voltammetry and flow injection analysis. A linear dynamic in the concentration range of 5 and 3000 mg/dl (r2 = 0.9) with a lower detection limit (LOD) of 5 mg/dl was achieved for BSA. In the case of IAP, the calibration curve was linear over the concentration range from 200 to 800 μg/ml, with an experimental LOD of 100 μg/dl. Excellent reproducibility was also demonstrated, suggested that direct electrochemical detection using BDD electrodes can be performed with advantages in terms of simplicity, sensitivity and stability.
AB - Direct oxidation peaks relating to proteins have been clearly observed by exploiting H-terminated boron-doped diamond (BDD) electrodes. Hydrogen generation by reduction treatment was enabled to provide the possibility of using BDD. The pH dependence of bovine serum albumin (BSA) oxidation suggested that the oxidation involved of at least three redox-active amino acid residues (cysteine, tryptophan and tyrosine). Furthermore, the electrochemical detection of not only BSA but also immunosuppressive acidic protein (IAP, a cancer marker) was demonstrated by using cyclic voltammetry and flow injection analysis. A linear dynamic in the concentration range of 5 and 3000 mg/dl (r2 = 0.9) with a lower detection limit (LOD) of 5 mg/dl was achieved for BSA. In the case of IAP, the calibration curve was linear over the concentration range from 200 to 800 μg/ml, with an experimental LOD of 100 μg/dl. Excellent reproducibility was also demonstrated, suggested that direct electrochemical detection using BDD electrodes can be performed with advantages in terms of simplicity, sensitivity and stability.
KW - Bovine serum albumin
KW - Direct electrochemical detection
KW - H-terminated boron-doped diamond electrode
KW - Immunosuppressive acidic protein
KW - Protein
UR - http://www.scopus.com/inward/record.url?scp=37449002227&partnerID=8YFLogxK
U2 - 10.1016/j.jelechem.2007.09.027
DO - 10.1016/j.jelechem.2007.09.027
M3 - Article
AN - SCOPUS:37449002227
SN - 1572-6657
VL - 612
SP - 201
EP - 207
JO - Journal of Electroanalytical Chemistry
JF - Journal of Electroanalytical Chemistry
IS - 2
ER -