T1 - Digital Filter Effect of the Ventilator Tester Parameters to Identify Inflation Phases
AU - Abuzairi, Tomy
AU - Irfan, Ahli
AU - Basari,
N1 - Funding Information:
We gratefully acknowledge the research funding from Kementerian Riset dan Teknologi/Badan Riset dan Inovasi Nasional through Penelitian Dasar Unggulan Perguruan Tinggi (PDUPT) 2021 Nomor: NKB-214/UN2.RST/HKP.05.00/2021.
Publisher Copyright:
© 2022 American Institute of Physics Inc.. All rights reserved.
PY - 2022/8/16
Y1 - 2022/8/16
N2 - A ventilator is a breathing support device that serves as a therapeutic tool or treatment tool for patients with respiratory system failure caused by various health problems or diseases. On ventilators, there are crucial parameters that need to be monitored in advance, such as inspiration-expiration (I:E) ratio, respiration rate, tidal volume, peak inspiration pressure (PIP), positive end-expiratory pressure (PEEP), and oxygen concentration. To monitor those parameters, a ventilator tester is needed. In this paper, we analyzed the effect of a digital filter in the ventilator tester, COVENT-Tester, to identify the inflation phase in the ventilator parameters. The results show that the digital filter is not effective in measuring I:E ratio and respiration rate because of the delay in inspiration and expiration time. However, the digital filter is effective in measuring tidal volume, PIP, PEEP, and oxygen concentration.
AB - A ventilator is a breathing support device that serves as a therapeutic tool or treatment tool for patients with respiratory system failure caused by various health problems or diseases. On ventilators, there are crucial parameters that need to be monitored in advance, such as inspiration-expiration (I:E) ratio, respiration rate, tidal volume, peak inspiration pressure (PIP), positive end-expiratory pressure (PEEP), and oxygen concentration. To monitor those parameters, a ventilator tester is needed. In this paper, we analyzed the effect of a digital filter in the ventilator tester, COVENT-Tester, to identify the inflation phase in the ventilator parameters. The results show that the digital filter is not effective in measuring I:E ratio and respiration rate because of the delay in inspiration and expiration time. However, the digital filter is effective in measuring tidal volume, PIP, PEEP, and oxygen concentration.
KW - Digital Filter
KW - Expiration
KW - Inspiration
KW - Respiration rate
KW - Ventilator tester
UR - http://www.scopus.com/inward/record.url?scp=85138286314&partnerID=8YFLogxK
U2 - 10.1063/5.0098209
DO - 10.1063/5.0098209
M3 - Conference contribution
AN - SCOPUS:85138286314
T3 - AIP Conference Proceedings
BT - 6th Biomedical Engineering''s Recent Progress in Biomaterials, Drugs Development, and Medical Devices
A2 - Rahman, Siti Fauziyah
A2 - Zakiyuddin, Ahmad
A2 - Whulanza, Yudan
A2 - Intan, Nurul
PB - American Institute of Physics Inc.
T2 - 6th International Symposium of Biomedical Engineering''s Recent Progress in Biomaterials, Drugs Development, and Medical Devices, ISBE 2021
Y2 - 7 July 2021 through 8 July 2021
ER -