TY - JOUR
T1 - Digital 3D microstructure analysis of concrete using X-Ray micro computed tomography SkyScan 1173
T2 - International Conference of Applied Science and Technology for Infrastructure Engineering 2017, ICASIE 2017
AU - Latief, F. D.E.
AU - Mohammad, I. H.
AU - Rarasati, A. D.
N1 - Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2017/11/23
Y1 - 2017/11/23
N2 - Digital imaging of a concrete sample using high resolution tomographic imaging by means of X-Ray Micro Computed Tomography (μ-CT) has been conducted to assess the characteristic of the sample's structure. A standard procedure of image acquisition, reconstruction, image processing of the method using a particular scanning device i.e., the Bruker SkyScan 1173 High Energy Micro-CT are elaborated. A qualitative and a quantitative analysis were briefly performed on the sample to deliver some basic ideas of the capability of the system and the bundled software package. Calculation of total VOI volume, object volume, percent of object volume, total VOI surface, object surface, object surface/volume ratio, object surface density, structure thickness, structure separation, total porosity were conducted and analysed. This paper should serve as a brief description of how the device can produce the preferred image quality as well as the ability of the bundled software packages to help in performing qualitative and quantitative analysis.
AB - Digital imaging of a concrete sample using high resolution tomographic imaging by means of X-Ray Micro Computed Tomography (μ-CT) has been conducted to assess the characteristic of the sample's structure. A standard procedure of image acquisition, reconstruction, image processing of the method using a particular scanning device i.e., the Bruker SkyScan 1173 High Energy Micro-CT are elaborated. A qualitative and a quantitative analysis were briefly performed on the sample to deliver some basic ideas of the capability of the system and the bundled software package. Calculation of total VOI volume, object volume, percent of object volume, total VOI surface, object surface, object surface/volume ratio, object surface density, structure thickness, structure separation, total porosity were conducted and analysed. This paper should serve as a brief description of how the device can produce the preferred image quality as well as the ability of the bundled software packages to help in performing qualitative and quantitative analysis.
UR - http://www.scopus.com/inward/record.url?scp=85037745350&partnerID=8YFLogxK
U2 - 10.1088/1757-899X/267/1/012020
DO - 10.1088/1757-899X/267/1/012020
M3 - Conference article
AN - SCOPUS:85037745350
SN - 1757-8981
VL - 267
JO - IOP Conference Series: Materials Science and Engineering
JF - IOP Conference Series: Materials Science and Engineering
IS - 1
M1 - 012020
Y2 - 5 August 2017
ER -