TY - JOUR
T1 - Development of inhomogeneity measurement system for type T thermocouple with local heating method
AU - Nugraha, Heri
AU - Prajitno, Prawito
AU - Achmadi, Aditya
AU - Tistomo, Arfan Sindhu
AU - Wismogroho, Agus Sukarto
AU - Imaduddin, Agung
AU - Yudanto, Sigit Dwi
AU - Herbirowo, Satrio
AU - Hendrik,
AU - Roberto, Rahadian
N1 - Funding Information:
This work was supported by the Saintek Scholarship 2018 from The Ministry of Research, Technology, and High Education Indonesia.
Publisher Copyright:
© 2021 Institute of Physics Publishing. All rights reserved.
PY - 2021/3/12
Y1 - 2021/3/12
N2 - The voltage of thermocouple during process contribution is determined by the absolute thermal electromotive force coefficient in each wire and the temperature difference across the section. This paper described the development of a system as a local heating method for measurements of inhomogeneities in type T thermocouples with various temperature scanning using hot air. The system could control automatically measurement voltage, temperature, distance, and speed of the stepper motor for moving the hot air scanning along with the thermocouple and control with temperature monitoring. Both the measuring and reference junctions were using an ice bath kept at 0 °C. In this paper calculation of interpretation of the measurement results of inhomogeneity using movable heating zone system of type T thermocouples and the system could detected inhomogeneity of thermocouple and there have different characteristics of voltage and seebeck effect.
AB - The voltage of thermocouple during process contribution is determined by the absolute thermal electromotive force coefficient in each wire and the temperature difference across the section. This paper described the development of a system as a local heating method for measurements of inhomogeneities in type T thermocouples with various temperature scanning using hot air. The system could control automatically measurement voltage, temperature, distance, and speed of the stepper motor for moving the hot air scanning along with the thermocouple and control with temperature monitoring. Both the measuring and reference junctions were using an ice bath kept at 0 °C. In this paper calculation of interpretation of the measurement results of inhomogeneity using movable heating zone system of type T thermocouples and the system could detected inhomogeneity of thermocouple and there have different characteristics of voltage and seebeck effect.
UR - http://www.scopus.com/inward/record.url?scp=85103276292&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/1825/1/012031
DO - 10.1088/1742-6596/1825/1/012031
M3 - Conference article
AN - SCOPUS:85103276292
SN - 1742-6588
VL - 1825
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 1
M1 - 012031
T2 - 10th International Conference on Physics and Its Applications, ICOPIA 2020
Y2 - 26 August 2020
ER -