TY - GEN
T1 - Design of portable electrocardiogram device using DSO138
AU - Abuzairi, Tomy
AU - Matondang, Josef Stevanus
AU - Purnamaningsih, Retno Wigajatri
AU - Basari, null
AU - Ratnasari, Anita
N1 - Publisher Copyright:
© 2018 Author(s). Published by AIP Publishing.
PY - 2018/2/13
Y1 - 2018/2/13
N2 - Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.
AB - Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.
KW - DSO138
KW - Portable
KW - electrocardiogram
KW - health monitoring
UR - http://www.scopus.com/inward/record.url?scp=85042390084&partnerID=8YFLogxK
U2 - 10.1063/1.5023975
DO - 10.1063/1.5023975
M3 - Conference contribution
AN - SCOPUS:85042390084
T3 - AIP Conference Proceedings
BT - 2nd Biomedical Engineering�s Recent Progress in Biomaterials, Drugs Development, and Medical Devices
A2 - Dhelika, Radon
A2 - Whulanza, Yudan
A2 - Ramahdita, Ghiska
A2 - Wulan, Praswasti P.D.K.
PB - American Institute of Physics Inc.
T2 - 2nd Biomedical Engineering's Recent Progress in Biomaterials, Drugs Development, and Medical Devices, ISBE 2017
Y2 - 25 July 2017 through 26 July 2017
ER -