TY - GEN
T1 - Consistency Evaluation of a Three-Axis Fiber Bragg Grating Accelerometer Sensor for AUV Thruster Vibration Measurement
AU - Sukapraja, Muhammad Alif Rahman
AU - Rahardjo, Sasono
AU - Purnamaningsih, Retno Wigajatri
AU - Rahmadiansyah, Maristya
AU - Dewi, Mustika Fitriana
AU - Pramudya, Tinova
N1 - Publisher Copyright:
© The Author(s), under exclusive license to Springer Nature Switzerland AG 2026.
PY - 2026
Y1 - 2026
N2 - This study evaluates the consistency of a three-axis Fiber Bragg Grating (FBG) accelerometer in detecting vibrations generated by an Autonomous Underwater Vehicle (AUV) thruster under static conditions. Experiments were performed in a freshwater pool, maintaining constant thruster power and sensor-thruster distance, with five repetitions for each configuration. The median Bragg wavelength from each trial was analyzed and compared with a static reference to determine wavelength shifts. Results show small wavelength variations with relatively high consistency when the vibration sources aligned with the Y-Axis (FBG Y) sensor, achieving a coefficient of variation below 1.3%. Although variability was observed attributed to reflected waves, turbulence, and the inherent sensitivity of the sensor, the overall response remained steady and repeatable.
AB - This study evaluates the consistency of a three-axis Fiber Bragg Grating (FBG) accelerometer in detecting vibrations generated by an Autonomous Underwater Vehicle (AUV) thruster under static conditions. Experiments were performed in a freshwater pool, maintaining constant thruster power and sensor-thruster distance, with five repetitions for each configuration. The median Bragg wavelength from each trial was analyzed and compared with a static reference to determine wavelength shifts. Results show small wavelength variations with relatively high consistency when the vibration sources aligned with the Y-Axis (FBG Y) sensor, achieving a coefficient of variation below 1.3%. Although variability was observed attributed to reflected waves, turbulence, and the inherent sensitivity of the sensor, the overall response remained steady and repeatable.
KW - Fiber Bragg Grating
KW - Three-Axis Accelerometer
KW - Underwater Vibration Measurement
UR - https://www.scopus.com/pages/publications/105048701789
U2 - 10.1007/978-3-032-25259-3_12
DO - 10.1007/978-3-032-25259-3_12
M3 - Conference contribution
AN - SCOPUS:105048701789
SN - 9783032252586
T3 - Lecture Notes in Electrical Engineering
SP - 135
EP - 142
BT - Proceedings of the 6th International Conference on Nano Electronics Research and Education (ICNERE2025) Joint with the 27th Takayanagi Kenjiro Memorial Symposium
A2 - Moraru, Daniel
A2 - Ono, Yukinori
A2 - Konno, Akinori
PB - Springer Science and Business Media Deutschland GmbH
T2 - 6th International Conference on Nano Electronics Research and Education, ICNERE 2025, jointly held with the 27th Takayanagi Kenjiro Memorial Symposium, 2025
Y2 - 21 October 2025 through 23 October 2025
ER -