Comparison of surface roughness of nanofilled and nanohybrid composite resins after polishing with a multi-step technique

B. S.H. Itanto, Munyati Usman, Anggraini Margono

Research output: Contribution to journalConference articlepeer-review

6 Citations (Scopus)

Abstract

To compare the surface roughness of nanofilled and nanohybrid composite resins after polishing using a multi-step technique. 40 composite resin specimens were divided into two groups (20 nanofilled specimens using Filtek Z350 XT [group A] and 20 nanohybrid specimens using Filtek Z250 XT [group B]), prepared, and then polished. After immersion in artificial saliva for 24 hours, the surface roughness was measured with a surface roughness tester. The mean surface roughness results along with the standard deviation of group A were 0.0967 μm ±0.0174, while the results of group B were 0.1217 μm ±0.0244. Statistically (with p = 0.05), there were significant differences between each group. The surface roughness of a nanofilled composite resin after polishing with a multi-step technique is better than that of a nanohybrid composite resin.

Original languageEnglish
Article number012091
JournalJournal of Physics: Conference Series
Volume884
Issue number1
DOIs
Publication statusPublished - 30 Aug 2017
Event1st Physics and Technologies in Medicine and Dentistry Symposium, PTMDS 2017 - Depok, West Java, Indonesia
Duration: 15 Jul 201716 Jul 2017

Fingerprint

Dive into the research topics of 'Comparison of surface roughness of nanofilled and nanohybrid composite resins after polishing with a multi-step technique'. Together they form a unique fingerprint.

Cite this