TY - JOUR
T1 - Circuit and Signal Processing for Capacitance Measurement of Breast Tissue
AU - Yusuf, Arba'i
AU - Sudibyo, S. harry
AU - Sudiana, Dodi
AU - Muttakin, Imamul
AU - Baidillah, Marlinr.
AU - Dasril, Dilla nelvo
AU - Widada, Wahyu
AU - Taruno, Warsitop.
PY - 2015/10/1
Y1 - 2015/10/1
N2 - In previous studies, electrical capacitance tomography has been developed and applied for imaging breast tissue to detect abnormalities within the breast caused by simple cysts, benign tumors and malignant cancers. For accurate screening and early detection of such abnormalities, high sensitive capacitance sensor is necessary. This study proposes a novel capacitance sensor circuit and signal conditioning and processing based on capacitance–voltage circuit for breast tissue measurement. The new sensor circuit design used a biopotential capacitance electrode, capable of measuring capacitance value with a resolution as low as 0.1 fF, a sensitivity of 1.6 V/pF, and linearity of 0.98. The experiment was conducted with a hemisphere 3D sensor 24 electrodes. The experiment strategy is as follow, first the system will be calibrated using network analyzer, secondly experiment using phantom 1, and the third experiment using phantom 2. In the design, we used a reference electrode made from fixed plate to measure capacitance inside the system, which will be used further for compensation against signal fluctuation caused by environmental condition such as humidity, temperature, pressure, etc. As a result, more stable system is achieved. Based on the experiment, the system can detect abnormalities of the human breast which are represented by two phantoms with different condition.
AB - In previous studies, electrical capacitance tomography has been developed and applied for imaging breast tissue to detect abnormalities within the breast caused by simple cysts, benign tumors and malignant cancers. For accurate screening and early detection of such abnormalities, high sensitive capacitance sensor is necessary. This study proposes a novel capacitance sensor circuit and signal conditioning and processing based on capacitance–voltage circuit for breast tissue measurement. The new sensor circuit design used a biopotential capacitance electrode, capable of measuring capacitance value with a resolution as low as 0.1 fF, a sensitivity of 1.6 V/pF, and linearity of 0.98. The experiment was conducted with a hemisphere 3D sensor 24 electrodes. The experiment strategy is as follow, first the system will be calibrated using network analyzer, secondly experiment using phantom 1, and the third experiment using phantom 2. In the design, we used a reference electrode made from fixed plate to measure capacitance inside the system, which will be used further for compensation against signal fluctuation caused by environmental condition such as humidity, temperature, pressure, etc. As a result, more stable system is achieved. Based on the experiment, the system can detect abnormalities of the human breast which are represented by two phantoms with different condition.
KW - Capacitance Measurement
KW - Signal Processing
KW - Sensitivity
KW - Breast Tissue
KW - Cancer Detection
KW - Biopotential Electrodes
UR - https://www.researchgate.net/publication/284709201_Circuit_and_Signal_Processing_for_Capacitance_Measurement_of_Breast_Tissue
U2 - 10.1166/asem.2015.1779
DO - 10.1166/asem.2015.1779
M3 - Article
SN - 2164-6627
VL - 7
SP - 900
EP - 905
JO - Advanced Science, Engineering and Medicine
JF - Advanced Science, Engineering and Medicine
IS - 10
ER -