TY - GEN
T1 - Application of remote sensing analysis and MT method for identification geothermal prospect zone in Mt. Endut
AU - Akbar, A. M.
AU - Permadi, A. N.
AU - Wildan, D.
AU - Sobirin, R.
AU - Supriyanto, null
N1 - Publisher Copyright:
© 2017 Author(s).
PY - 2017/7/10
Y1 - 2017/7/10
N2 - Mount Endut is located at Banten Province, 40 km southward Rangkasbitung City, with geographic UTM position between 9261000-9274000 N and 639000-652000 E. Preliminary survey at Mt. Endut was geological and geochemical survey in 2006, resistivity survey and MT survey in 2007 with 27 measurement point. All survey conducted by Pusat Sumber Daya Geologi (PSDG). According to result of premilinary survey, Mt. Endut is dominated by quartenary volcanic rock produced by Mt. Endut, which breakthrough tertiary sediment layer. NE to SW normal fault produced surface manifestation, namely Cikawah (CKW) hot spring and Handeleum (HDL) hot spring. According to SiO2 and NaK geothermometer, subsurface temperature of Mt Endut is ranging from 162 to 180 °C. Apparent resistivity maps show that thermal manifestation areas coincide with pronounced high anomaly due to resistive intrusion bodies contrast to conductive sedimentary basements. In order to delineate permeability zone, fracture fault density (FFD) analysis from remote sensing image is carry out. FFD analysis from lansdat 7 image shows the area on westward flank of Mt. Endut have high fracture fault density (162-276 m/km2), higher than it's surrounding area and can be assume that area is weak zone and have high permeability. That's structure density anomaly coincide with low resistivity from Magnetotelluric data. Resistivity structure from Magnetotelluric data shows western flank have low permeability layer (14-27 Ohmm) with average thickness 250 m. Below this layer there is layer with higher resistivity (37-100 Ohmm) with ±1000 m depth and interpreted as shallow reservoir. Massive resistif intrusive bodies act controlled the surface manifestation, and act as boundary and bounded the geothermal system in western part of Mt. Endut.
AB - Mount Endut is located at Banten Province, 40 km southward Rangkasbitung City, with geographic UTM position between 9261000-9274000 N and 639000-652000 E. Preliminary survey at Mt. Endut was geological and geochemical survey in 2006, resistivity survey and MT survey in 2007 with 27 measurement point. All survey conducted by Pusat Sumber Daya Geologi (PSDG). According to result of premilinary survey, Mt. Endut is dominated by quartenary volcanic rock produced by Mt. Endut, which breakthrough tertiary sediment layer. NE to SW normal fault produced surface manifestation, namely Cikawah (CKW) hot spring and Handeleum (HDL) hot spring. According to SiO2 and NaK geothermometer, subsurface temperature of Mt Endut is ranging from 162 to 180 °C. Apparent resistivity maps show that thermal manifestation areas coincide with pronounced high anomaly due to resistive intrusion bodies contrast to conductive sedimentary basements. In order to delineate permeability zone, fracture fault density (FFD) analysis from remote sensing image is carry out. FFD analysis from lansdat 7 image shows the area on westward flank of Mt. Endut have high fracture fault density (162-276 m/km2), higher than it's surrounding area and can be assume that area is weak zone and have high permeability. That's structure density anomaly coincide with low resistivity from Magnetotelluric data. Resistivity structure from Magnetotelluric data shows western flank have low permeability layer (14-27 Ohmm) with average thickness 250 m. Below this layer there is layer with higher resistivity (37-100 Ohmm) with ±1000 m depth and interpreted as shallow reservoir. Massive resistif intrusive bodies act controlled the surface manifestation, and act as boundary and bounded the geothermal system in western part of Mt. Endut.
UR - http://www.scopus.com/inward/record.url?scp=85026266207&partnerID=8YFLogxK
U2 - 10.1063/1.4991287
DO - 10.1063/1.4991287
M3 - Conference contribution
AN - SCOPUS:85026266207
T3 - AIP Conference Proceedings
BT - International Symposium on Current Progress in Mathematics and Sciences 2016, ISCPMS 2016
A2 - Sugeng, Kiki Ariyanti
A2 - Triyono, Djoko
A2 - Mart, Terry
PB - American Institute of Physics Inc.
T2 - 2nd International Symposium on Current Progress in Mathematics and Sciences 2016, ISCPMS 2016
Y2 - 1 November 2016 through 2 November 2016
ER -