TY - JOUR
T1 - Analysis of implementation UPFC for optimizing power flow & improving power system stability in Z power system
AU - Nugroho, A. A.
AU - Rahardjo, A.
AU - Setiawan, A.
AU - Jufri, F. H.
AU - Husnayain, F.
N1 - Funding Information:
This research is funded by research grant of HIBAH PITTA B .00/2019 from Universitas Indonesia
Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2019/12/10
Y1 - 2019/12/10
N2 - In electric power systems, it will started from the generation phase until the distribution phase through transmission lines must take place well. The purpose of study is to analyze the implementation in optimizing the power flow and improving stability in Z Power System. Therefore, it is necessary to have sufficient electricity distribution so that the electricity sent can be as efficient as possible. In the Z electric power system, there are many problems in electric power transmission, namely loading on uneven channels and the threat of extinguishing in the event of a disturbance. Uneven load is caused by differences in impedance on the channel. Blackouts occur because the channel on the Z is a generator evacuation route where the area is crucial if a disturbance occurs. Therefore, a tool is needed to prevent it. One solution to this problem is to use a power electronics device called UPFC. The simulation results show an even distribution on the all transmission lines connected to substation of Generators will be decrease up more than 3% of the normal loading. In addition, the UPFC can also improve stability by compensating for the active power and reactive power needed by the system.
AB - In electric power systems, it will started from the generation phase until the distribution phase through transmission lines must take place well. The purpose of study is to analyze the implementation in optimizing the power flow and improving stability in Z Power System. Therefore, it is necessary to have sufficient electricity distribution so that the electricity sent can be as efficient as possible. In the Z electric power system, there are many problems in electric power transmission, namely loading on uneven channels and the threat of extinguishing in the event of a disturbance. Uneven load is caused by differences in impedance on the channel. Blackouts occur because the channel on the Z is a generator evacuation route where the area is crucial if a disturbance occurs. Therefore, a tool is needed to prevent it. One solution to this problem is to use a power electronics device called UPFC. The simulation results show an even distribution on the all transmission lines connected to substation of Generators will be decrease up more than 3% of the normal loading. In addition, the UPFC can also improve stability by compensating for the active power and reactive power needed by the system.
UR - http://www.scopus.com/inward/record.url?scp=85078221687&partnerID=8YFLogxK
U2 - 10.1088/1757-899X/673/1/012067
DO - 10.1088/1757-899X/673/1/012067
M3 - Conference article
AN - SCOPUS:85078221687
SN - 1757-8981
VL - 673
JO - IOP Conference Series: Materials Science and Engineering
JF - IOP Conference Series: Materials Science and Engineering
IS - 1
M1 - 012067
T2 - Broad Exposure to Science and Technology 2019, BEST 2019
Y2 - 7 August 2019 through 8 August 2019
ER -