T1 - A Comparative Study of PTS and Manual Transportation for Platelet Count and Aggregation Test
AU - Adiyanti, Sri Suryo
AU - Setiadi, Bernadette Elvina
N1 - Publisher Copyright:
© 2023, Indonesian Association of Clinical Pathology and Laboratory Medicine. All rights reserved.
PY - 2023/5/5
Y1 - 2023/5/5
N2 - The transportation effect of the Pneumatic Tube System (PTS) on platelet activity remains controversial. This study aimed to analyze the effect of PTS in the platelet aggregation test in Dr. Cipto Mangunkusumo Hospital, Jakarta. This cross-sectional study was carried out in the Clinical Pathology Laboratory of Dr. Cipto Mangunkusumo Hospital (RSUPNCM) from March to April 2021. There were 50 subjects involved in this study, each of whom 6 sodium citrate blood tubes were extracted. Three tubes were sent through PTS while the rest were transported manually. All tubes were then tested for platelet count and platelet aggregation using ADP agonists of 1 μM, 5 μM, and 10 μM. There was a lower platelet count (p=0.046) and platelet aggregation in ADP 1 μM (p=0.037), ADP 5 μM (p <0.001), and ADP 10 μM (p <0.001) at PTS-transported samples. Eleven samples were interpreted distinctively as low platelet aggregation in PTS transportation became normal in manual delivery. Cohen's Kappa value was 0.51 (p <0.001). A decreasing platelet count and platelet aggregation in PTS samples indicated that acceleration and deceleration during transportation could lead to platelet activation, thus resulting in a lower result after being added to an agonist. Cohen's Kappa test showed that manual transportation could not be replaced with PTS for the platelet aggregation test. Platelet count and platelet aggregation were found to be lower in PTS-transported samples. It was suggested to centralize specimen taking for platelet aggregation tests, thus manual transportation can be conducted more efficiently.
AB - The transportation effect of the Pneumatic Tube System (PTS) on platelet activity remains controversial. This study aimed to analyze the effect of PTS in the platelet aggregation test in Dr. Cipto Mangunkusumo Hospital, Jakarta. This cross-sectional study was carried out in the Clinical Pathology Laboratory of Dr. Cipto Mangunkusumo Hospital (RSUPNCM) from March to April 2021. There were 50 subjects involved in this study, each of whom 6 sodium citrate blood tubes were extracted. Three tubes were sent through PTS while the rest were transported manually. All tubes were then tested for platelet count and platelet aggregation using ADP agonists of 1 μM, 5 μM, and 10 μM. There was a lower platelet count (p=0.046) and platelet aggregation in ADP 1 μM (p=0.037), ADP 5 μM (p <0.001), and ADP 10 μM (p <0.001) at PTS-transported samples. Eleven samples were interpreted distinctively as low platelet aggregation in PTS transportation became normal in manual delivery. Cohen's Kappa value was 0.51 (p <0.001). A decreasing platelet count and platelet aggregation in PTS samples indicated that acceleration and deceleration during transportation could lead to platelet activation, thus resulting in a lower result after being added to an agonist. Cohen's Kappa test showed that manual transportation could not be replaced with PTS for the platelet aggregation test. Platelet count and platelet aggregation were found to be lower in PTS-transported samples. It was suggested to centralize specimen taking for platelet aggregation tests, thus manual transportation can be conducted more efficiently.
KW - manual transportation
KW - platelet aggregation
KW - Pneumatic tube system
UR - http://www.scopus.com/inward/record.url?scp=85188586923&partnerID=8YFLogxK
U2 - 10.24293/ijcpml.v29i2.2010
DO - 10.24293/ijcpml.v29i2.2010
M3 - Article
AN - SCOPUS:85188586923
SN - 0854-4263
VL - 29
SP - 144
EP - 149
JO - Indonesian Journal of Clinical Pathology and Medical Laboratory
JF - Indonesian Journal of Clinical Pathology and Medical Laboratory
IS - 2
ER -